KN-3237 AAS for Testing Lead in Gasoline
KN-3237 AAS for Testing Lead in Gasoline

AAS.png

 KN-3237 AAS for for Testing Lead in Gasoline

Overview

  KN-3237 AAS for for Testing Lead in Gasoline conforms to ASTM D3237 Standard Test Method for Lead in Gasoline by Atomic Absorption Spectroscopy This AAS covers the determination of the total lead content of gasoline within the concentration range of 0.010 to 0.10 g of lead/U.S. gal (2.5 to 25 mg/L). This tester compensates for variations in gasoline composition and is independent of lead alkyl type.

The products include the flame, graphite furnace and hydride generation system, which can be equipped with various accessories, flexible configuration program can meet different customer demand. KN-3237 atomic absorption spectrometer can be used for analysis of complex samples, full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.


Main features

 

High precision automatic optical system

     1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively preheating

 

Polymer spray chamber

       Polymer materials corrosion spray chamber, acid and alkali resistance, including hydrofluoric acid, either organic or inorganic solution can be the highest sensitivity and stability

 

Titanium burner

       Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type, corrosion resistant, resistant to high salt, greatly improve the analysis efficiency and accuracy of the flame

 

Automatic analysis

       It can automatically accomplish safety ignition, extinction and switching, reliable structure, low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.

      The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automatic wavelength scanning and searching peak

 

Software function

       High intelligent software, powerful function, friendly interface English operation. Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

 

Graphite furnace temperature control

       Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that the measured elements has the highest sensitivity; furnace enriched up to 20 times, the longitudinal optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade.

 

High technology index

KN-3237 atomic absorption spectrophotometer elements test sensitivity meet international best level, sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the stability is better than 0.005Abs/4h

 

Background correction system

       Using deuterium hollow cathode lamp advanced and self absorption background deduction of background correction, to eliminate the interference of molecular absorption of low content determination, reducing the noise emission of deuterium lamp and prolongs the service life, has excellent stability. Deuterium lamp background signal for 1A, background correction ability > 50 times


Intelligent analysis

Great intelligence, humanized design, flame and graphite furnace atomizer automatic switching, automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment, automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow. In the case of power failure, misoperation, acetylene leakage, the system will automatically start the safety protection function

 

Automatic sampler

Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with intelligent online dilution and concentration function.

 

Technical parameters

                            Mainframe

Model

:

AA-1800C

Light Source

:

≤6 lamps automatic turret, automatic alignment

Power Supply

:

110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current

:

pulsed power supply

Optical System

:

large 1800 /mm grating ruling, full closed optical system

Wavelength Range

:

180nm-900nm                                                                                                 

Automatically peak find a key optical optimization function

Wavelength Accuracy

:

≤0.15nm

Wavelength Repeatability

:

±0.1nm

Spectral Bandwidth

:

0nm、0.2nm、0.4nm、1.0nm、2.0nm

(5 steps with automatic changeover)

Baseline Stability

:

≤±0.002A/30 min (Static)     

≤±0.005A/30min (Dynamic)

Absorbance Range

:

0-4A

                     Flame Analytical System

Detector

:

imported photomultiplier tube

Burner Head

:

full titanium combustion head, 50mm or 100mm general combustion head

Atomization Chamber

:

polymer explosion-proof spray chamber

Nebulizer

:

atomizer efficient glass atomizer, can also be customized

Ignition Type

:

microcomputer control, automatic ignition

Gas Control

:

automatic gas control system

Detection Limits(Cu)

:

0.002μg/mL

Precision

:

RSD≤0.5%




                Graphite Furnace Analytical System

Heating Mode

:

vertical heating

Temperature Control Method

:

vertical optical temperature monitoring graphite tube wall temperature

Temperature Range

:

room temperature to 3000℃

The Program

:

automatic temperature control up to 20 order

Temperature Control

:

the furnace enriched up to 20 times

Characteristics Volume

:

0.5 × 10-12g (Cd)

Detection Limit

:

0.4 × 10-12g (Cd)

Precision

:

RSD≤3%

The Cooling Water

:

can choose cooling water circulation system

Safety

:

the graphite tube damage, water flow

air pressure and other alarmtemperature overheating protection




                  Autosampler Graphite Furnace

Sample Tray

:

70 sample cups, 6 reagent cup

Sample Volume

:

1-100μl

The Smallest Lincrement

:

0.1 μl

The Volume of Sample

:

better than 1%(at the time of 10mL-100mL)

Repeatability Volume

Repeated Sampling Frequency

:

up to 99 Times

Cleaning and Waste

:

each 500mL

Container Volume