KN-170Z Automatic Abel Closed Cup Flash Point Tester
KN-170Z Automatic Abel Closed Cup Flash Point Tester

abel.png

KN-170Z Automatic Abel Closed Cup Flash Point Tester

Overview

KN-170Z Automatic Abel Closed Cup Flash Point Tester conforms to IP170 Petroleum products and other liquids -- Determination of flash point -- Abel closed cup method and ISO 13736 Petroleum Products and Other Liquids - Determination of Flash Point - Abel Closed Cup Method. This International Standard specifies a method for the determination of the closed cup flash point of petroleum products and other liquids having flash points between -30 and 70 inclusive.   However, the precision given for the method is only valid for flash points in the range -5 to 66.5. This standard is not acceptable to water borne paints which may however be tested using ISO 3679


Features

1.      Control system: bilingual menus in Chinese and English, true color GUI touch screen interface design, intuitive display, easy operation, reasonable structure, fast test speed, wide test range, good repeatability and authenticity, etc. The test process is fully automated, and the temperature, time and other parameters involved will be displayed on the LCD screen, on which the user will also see the working status of the instrument and related operation prompts. Only need to preset the expected flash point or starting temperature of the sample to be measured, and the instrument can start to cool and heat up at the specified rate, and then perform ignition, flash point detection, air cooling, and printout. The instrument will automatically correct the test results according to changes in atmospheric pressure. The instrument has powerful data processing capabilities: be able to save 1000 test records for checking and printing. It can save the preset parameters before each shutdown.

2.      Double ignition mode: the ignition mode adopts electronic ignition or gas ignition, operator can select the ignition method as real demands, and there is no difference of both methods

3.      Split independent design: The cup lid assembly, flash point sensor and temperature sensor are all split independent design, which makes it easier to replace each accessory.

4.      Self-check and self-diagnosis: When the instrument is turned on, the flash point sensor, Pt100 oil temperature sensor, electronic igniter, thermofuse, etc. will be automatically checked; At the same time, self-check will be carried out on the ignition, stirring arm, cooling and heating system start/reset, etc. If there is a fault or the connection is not normal, the instrument will beep and give an alarm, and the screen text prompts “××× abnormal, please check whether it is connected”


Technical parameters

1.      Test temperature range: -30~80

2.      Temperature detection: Platinum resistor, Pt100

3.      Display mode: 7-inch LCD

4.      Cooling mode: Compressor (connect external circulating water bath)

5.      Heating rate: 1/min, Temperature Resolution: 0.1

6.      Stirring speed: 0.5r/s (30rpm)

7.      Ignition mode: Electric or gas

8.      Ambient requirements: 10~40, Relative humidity≤85%

9.      Power consumption≤450W

10.   Low temperature circulating bath≤1000W



Copyright:KAYCAN INSTRUMENT(DaLian) Co.,Ltd    Record No:辽ICP备18001461号-2